Back

Flameproof - explosionproof motors

In more than of fifty years of activity, Cemp has created one of the most comprehensive range of electric motors for hazardous areas available today on the market:

  • Ex-d; Ed-de flameproof motors

  • Ex-d; Ed-de flameproof motors with brake

  • Ex-nA non sparking motors

 

Cemp’s customer service ensures technical competence, flexible response and on time deliveries.



Series A cast-iron
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 1M2, 2G
  • Group I (mine), IIB, IIC
  • Temperature class T3, T4, T5, T6
  • Protection IP55 ÷ IP66
  • Power 0.05 ÷ 240 kW
  • Three-phase 1 or 2 speed
  • Single-phase (frame size 63÷100)
  • Ventilation IC410, IC411, IC416, IC418
  • Available IE2, IE3
  • Atex and IECEx certificated
Series F aluminium
IEC 60079-0, IEC 60079-1, IEC 60079-7
  • Ex-d, Ex-de
  • Frame size 56 ÷ 80
  • ATEX category 2D, 2G, 2GD
  • Group IIB, IIC
  • Temperature class T4, T5, T6
  • To Norms IEC 61241-0, IEC 61241-1
  • A21 - tD
  • Protection IP55, IP65
  • Maximum surface temperature [°C] T125, T85, T70
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Power 0.06 ÷ 1.5 kW
  • Three-phase 1 or 2 speed
  • Single-phase
  • Ventilated, unventilated
  • PAD mounting
Series D, H, cast-iron with brake
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 2G
  • Group IIB, IIC
  • Temperature class T3, T4
  • Protection IP55 ÷ IP65
  • Power 0.05 ÷ 132 kW
  • Three-phase 1 or 2 speed
  • A.C. or D.C. disk brake
  • Ventilation IC410, IC411, IC416, IC418
  • Available IE2, IE3
  • Atex and IECEx certificated   
Series F-F aluminium with brake
To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
  • Ex-d, Ex-de
  • Frame size 63 ÷ 80
  • ATEX category 2D, 2G, 2GD
  • Group IIB, IIC
  • Temperature class T4, T5
  • To Norms IEC 61241-0, IEC 61241-1
  • A21 - tD
  • Protection IP55, IP65
  • Maximum surface temperature [°C] T125, T85, T70
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Power 0.12 ÷ 1.5 kW
  • Three-phase 1 or 2 speed, inverter
  • A.C. or D.C. disk brake
Series A cast-iron for inverter
To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 2G
  • Group IIB, IIC
  • Temperature class T3, T4
  • Protection IP55 ÷ IP66
  • Power 0.05 ÷ 240 kW
  • Three-phase
  • Ventilation IC410, IC411, IC416, IC418
  • Available IE2, IE3
  • Atex and IECEx certificated 
Series F aluminium for inverter
IEC 60079-0, IEC 60079-1, IEC 60079-7
  • Ex-d, Ex-de
  • Frame size 56 ÷ 80
  • ATEX category 2D, 2G, 2GD
  • Group IIB, IIC
  • Temperature class T4, T5, T6
  • To Norms IEC 61241-0, IEC 61241-1
  • A21 - tD
  • Protection IP55, IP65
  • Maximum surface temperature [°C] T125, T85, T70
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Power 0.06 ÷ 1.5 kW
  • Three-phase 1 or 2 speed
  • Single-phase
  • Self cooled (IC411); forced cooling (IC416); unventilated  (IC418)
  • PAD mounting